  • UL Wire Styles Compared: UL1007 vs UL1015 vs UL1571 vs UL2464

UL Wire Styles Compared: UL1007 vs UL1015 vs UL1571 vs UL2464

Oct 19, 2026

Two spools of wire can look the same on a bench and behave nothing alike in the field. One is rated 300 V at 80°C. The other handles 600 V at 105°C, and it is twice as thick because of it.

Design reviews rarely fail on the connector. They fail on the wire style, because someone copied an old BOM and never checked the rating.

Here is how UL1007, UL1015, UL1571 and UL2464 differ, and when each one is the right call.

The short answer: UL1007 is the 300 V, 80°C workhorse for internal wiring. UL1015 doubles the wall and takes you to 600 V and 105°C. UL1571 is a 30 V, 80°C thin-wall wire for tight, low-voltage runs. UL2464 is a multi-conductor jacketed cable with an optional shield, built for data and signal.

If you already know the harness needs UL PVC Electronic Wire and just want the right style, the table below is the short version.

The numbers side by side

Style Rating Insulation AWG range Where it goes
UL1007300 V, 80°CPVC, 0.015 in32 to 16Internal wiring of appliances and electronics
UL1015600 V, 105°CPVC, about 0.030 in30 to 6Control panels, power runs, higher heat
UL157130 V, 80°CPVC, down to 2 mil32 to 16, down to 50Class 2 circuits, dense electronics
UL2464300 V, 80°CPVC cores, PVC jacket16 to 28 typicalData, signal, computer peripherals

What UL 758 actually controls

UL 758 is the standard for Appliance Wiring Material, or AWM. Each style number is a construction recipe: conductor size range, insulation material, wall thickness, temperature, voltage and flame rating. The style number is not a quality grade. It is a specification, and two factories can build the same style to very different levels of care.

That is why the print on the jacket matters more than the color of the spool. A proper AWM print carries the style, the AWG, the temperature and voltage rating, and the manufacturer's UL file number. Anyone can check that file number on UL Product iQ in about a minute.

UL1007: the 300 V default

UL1007 is the wire most internal assemblies start with. PVC insulation, 0.015 in nominal wall, 32 to 16 AWG, 300 V, 80°C, VW-1 flame rated. It bends easily, strips cleanly and takes up little space in a duct.

Most UL PVC Electronic Wire for Household Appliances sits at 300 V or below, which is exactly where 1007 lands. The 80°C limit is the part to watch. Inside a sealed enclosure sitting next to a transformer, ambient plus temperature rise can push past 80°C faster than the thermal calculation suggests. If the box runs warm, UL1015 or an XLPE style is the safer call, even when the voltage never goes above 300 V.

Many spools carry a dual print such as UL1007/1569, and sometimes a CSA TR-64 rating. That dual rating is useful for North American builds. It is not a substitute for checking what the print actually says.

UL1015: 600 V and 105°C

UL1015 takes the same PVC construction and doubles the wall, roughly 0.030 in at 16 AWG. That buys 600 V and 105°C, and it costs you diameter and stiffness.

On a panel with fifty conductors in a duct, the extra diameter adds up. So does the bend radius. If you switch a harness from 1007 to 1015 late in a project, recheck the duct fill and the routing before you release the drawing.

Where 1015 earns its price: control cabinets, power supply leads, motor connections, and anything that runs hot or sits on the high side of a 300 V rail.

UL1571: thin wall, low voltage, tight spaces

UL1571 Hook-up wire is a different animal. It is rated 30 V at 80°C, with a wall that can go as thin as 2 mil, typically around 4 mil on 24 to 32 AWG. Its job is internal wiring of Class 2 circuits in electronic equipment.

That thin wall is the point. It lets you run a lot of conductors through a small housing, and it stays flexible in a way 1007 does not. The trade-off is mechanical protection. Where the wire rubs against a chassis edge or passes through a metal hole, add sleeving or a grommet. Thin PVC does not forgive abrasion.

Do not use 1571 as a power wire, and do not assume it can replace 1007 just because the gauge matches. The voltage rating is ten times lower.

UL2464: multi-conductor with a jacket

UL2464 is a cable, not a hook-up wire. Several insulated conductors, usually twisted, wrapped in foil or braid, with a drain wire and a PVC jacket. 300 V, 80°C, VW-1, commonly 16 to 28 AWG.

You reach for it when signals travel together and the environment is noisy: RS-232 links, computer peripherals, instrumentation, audio, point-of-sale hardware. The shield does something only if you terminate it properly. For low-frequency signals, grounding the drain at one end usually avoids a ground loop. For higher-frequency noise, bonding both ends to chassis is often the better choice. Either way, a shield with a floating drain is decoration.

One caution: 2464 is a general-purpose AWM cable, not a fieldbus cable. If the protocol specifies impedance, capacitance or a specific cable type, use the cable the protocol asks for.

How to choose in 60 seconds

If your situation is Choose
Under 300 V, inside the device, tight routingUL1007
300 to 600 V, or ambient above 80°CUL1015
Class 2 signal in a dense housingUL1571
Several signals in one run, EMI nearbyUL2464

Reading the print on the wire

Good incoming inspection takes five minutes:

  • Read the surface print. Style, AWG, temperature, voltage, UL file number.
  • Check the file number on UL Product iQ. Make sure the style is actually covered.
  • Measure the insulation wall at a cut end with a micrometer. A 1007 that measures like a 1015 is not a bargain, it is a different part.
  • Count the strands. Copper is the easiest place to hide a cost cut.
  • Bend it tight around a mandrel and look for cracking, especially if the spool has been sitting in a warehouse.

Where cheap wire shows up later

Not in the first article. In the field, or in the certification lab. A wall that runs under the minimum can crack at a bend after a few thermal cycles. Recycled PVC ages faster and fails the elongation check. Under-filled conductors run hot at the same current.

The expensive version of this problem is a final product that fails UL because the internal wiring is not what the file says it is. Wire is a small line in the BOM. The recall is not.

Bottom line

Pick the style by rating first, then by routing and cost. 1007 for 300 V inside the box, 1015 when the voltage or the heat goes up, 1571 when space is the constraint and the circuit is Class 2, 2464 when signals need to travel together with a shield around them.